Practical aspects of insulin pen devices.
J Diabetes Sci Technol. 2010 May;4(3):522-31
Authors: Pearson TL
Insulin pen devices have several advantages over the traditional vial-and-syringe method of insulin delivery, including improved patient satisfaction and adherence, greater ease of use, superior accuracy for delivering small doses of insulin, greater social acceptability, and less reported injection pain. In recent years, pens have become increasingly user-friendly, and some models are highly intuitive to use, requiring little or no instruction. Despite this progress, uptake of these devices in the United States has not matched that in many other areas of the world. There is a need for improved awareness of the current characteristics of insulin pen devices among United States health care professionals. Knowledge of the design improvements that have been incorporated into pens, both to address patient needs and as a result of the improved technology behind the device mechanics, is essential to promoting the use of insulin pen devices. This review highlights some of the practical aspects of pen use and discusses the factors to be considered when selecting among different insulin pens.
PMID: 20513316 [PubMed - indexed for MEDLINE]
[Read more →]
Tags: J Diabetes Sci Technol
Evolution of diabetes insulin delivery devices.
J Diabetes Sci Technol. 2010 May;4(3):505-13
Authors: Selam JL
The first manufactured insulin pump was introduced in the 1970s and the first insulin pens in 1985; since then, many improvements have been made to both devices. The advantages of pens over syringes have been confirmed in numerous studies and include greater accuracy, ease of use, patient satisfaction, quality of life, and adherence. United States claims database analyses indicate that the improved adherence made possible by use of an insulin pen has the potential to reduce diabetes care costs when compared with using a vial and syringe. Features of certain advanced pump models include the ability to connect wirelessly to a blood glucose meter or to a subcutaneous interstitial glucose sensor for semicontinuous glucose-driven insulin rate adjustment. A new trend in the design of insulin pumps is the tubing-free patch pump that adheres directly to the skin. The low rate of insulin pen usage in the United States compared with European countries and the fact that many patients report that they are not offered the option of an insulin pen by their physician suggest that there is a need to increase patient and provider awareness of the currently available devices for insulin administration.
PMID: 20513314 [PubMed - indexed for MEDLINE]
[Read more →]
Tags: J Diabetes Sci Technol
Outpatient-to-inpatient transition of insulin pump therapy: successes and continuing challenges.
J Diabetes Sci Technol. 2010 Jul;4(4):863-72
Authors: Nassar AA, Partlow BJ, Boyle ME, Castro JC, Bourgeois PB, Cook CB
BACKGROUND: Insulin pump therapy is a complex technology prone to errors when employed in the hospital setting. When patients on insulin pump therapy require hospitalization, practitioners caring for them must decide whether to allow continued pump use. We provide the largest review regarding transitioning insulin pump therapy from the outpatient to inpatient setting. METHOD: Records of inpatient insulin pump users were retrospectively analyzed at a metropolitan Phoenix hospital between January 2006 and December 2009. Adherence to institutional procedures on insulin pump use was assessed, glycemic control was determined, and adverse events were examined. RESULTS: We examined records on 65 patients with insulin pumps, totaling 125 hospitalizations. Mean (standard deviation) patient age was 55 (17) years, diabetes duration was 27 (14) years, pump duration was 6 (5) years, length of hospital stay was 4.7 (6.3) days, hemoglobin A1c was 7.3 (1.3)%, 85% had type 1 diabetes mellitus, 57% were women, and 97% were white. Admissions involving insulin pumps increased (23 in 2006, 17 in 2007, 40 in 2008, and 45 in 2009). Insulin pump therapy was continued in 83 (66%) hospitalizations. Among these hospitalizations, endocrinology consultations were obtained in 89%, consent agreements were found in 83%, insulin pump order sets were completed in 89%, admission glucose was checked in 100%, and nursing assessments of pump insertion sites were documented in 89%, but bedside insulin pump flow sheets were found in only 55%. Mean glucose of 175 (57) mg/dl was not significantly different than that in hospitalizations where insulin pumps were discontinued [175 (42) mg/dl] or used intermittently [177 (7) mg/dl]. There was one instance of a pump catheter kinking; however, no other adverse events (pump site infections, mechanical pump failure, diabetic ketoacidosis) were observed, and there were no use-related fatalities. CONCLUSIONS: Most patients using insulin pumps can safely have their therapy transitioned when hospitalized. A policy on inpatient continuous subcutaneous insulin infusion use can be successfully implemented. Compliance with required procedures can be achieved, although there was room to improve adherence with some process measures. Further study is needed to determine how to optimize glycemic control when pumps are allowed during hospitalization.
PMID: 20663450 [PubMed - indexed for MEDLINE]