Please note: This website is for discussion purposes only. The information provided at this website is not intended to provide treatment advice, or to diagnose or treat any medical disorder. The creator of this website is not responsible for events that occur as a result of decisions made based on the information presented here.

Citations powered by PubMed

Entries Tagged as 'Diabetes Technol Ther'

Evaluating Inpatient Glycemic Management: The Quality Hyperglycemia Score.

April 25th, 2011 · Start a Discussion

Evaluating Inpatient Glycemic Management: The Quality Hyperglycemia Score.
Diabetes Technol Ther. 2011 Apr 21;
Authors: Hendrickson KC, Bozzo JE, Zimkus J, Scorel K, Maerz L, Balcezak T, Inzucchi SE
Abstract Background…

[Read more →]

Tags: Diabetes Technol Ther

Accuracy of whole blood glucose measurement when venous catheter blood samples are used on glucose meters.

March 26th, 2010 · Start a Discussion

Related Articles

Accuracy of whole blood glucose measurement when venous catheter blood samples are used on glucose meters.

Diabetes Technol Ther. 2009 Dec;11(12):819-25

Authors: Karon BS, Koch CD, Wockenfus AM, Brown JK

BACKGROUND: Previous studies have found positive bias and frequent outliers when central venous catheter (CVC) whole blood is used to dose glucose meters. We designed a study to determine whether positive bias and outliers with CVC whole blood glucose samples are due to exogenous glucose contamination of CVC samples, inherent bias and imprecision of glucose meters, or properties of CVC whole blood that interfere with the function of some glucose meters. METHODS: We studied the relationship between venous whole blood and venous plasma glucose drawn by venipuncture to CVC whole blood and CVC plasma glucose in 50 hospitalized patients. In 27 patients whole blood glucose was measured on both the Accu-Chek Inform (Roche Diagnostics, Indianapolis, IN) and StatStrip (Nova Biomedical, Waltham, MA). RESULTS: By comparing CVC plasma to venous plasma glucose, we determined that contamination of CVC samples with exogenous glucose was uncommon. On the Inform meter outliers were approximately twice as common with CVC whole blood compared to venous whole blood. In 27 patients who had CVC whole blood analyzed by both Inform and StatStrip, outliers occurred approximately twice as often on the Inform compared to the StatStrip. Accounting for CVC samples contaminated with exogenous glucose, outliers on the StatStrip did not occur significantly more often using CVC whole blood compared to venous whole blood. CONCLUSIONS: Properties unique to CVC whole blood differentially affect glucose meter bias and imprecision. Device selection is critical in practices that wish to use CVC whole blood to monitor glucose concentration in hospitalized patients.

PMID: 20001684 [PubMed - indexed for MEDLINE]

[Read more →]

Tags: Diabetes Technol Ther