Entries Tagged as 'Conf Proc IEEE Eng Med Biol Soc'
SpO2 sensor embedded in a finger ring: design and implementation.
Conf Proc IEEE Eng Med Biol Soc. 2006;1:4295-8
Authors: Solà J, Castoldi S, Chételat O, Correvon M, Dasen S, Droz S, Jacob N, Kormann R, Neumann V, Perrenoud A, Pilloud P, Verjus C, Viardot G
A novel concept of Oxygen Saturation (SpO2) sensor embedded in a finger ring is presented in this paper. Due to the mechanical conception of the probe, the sensor fits any finger topology and assures a constant force applied to the phalanx. Ambient light artifacts are rejected at the analog electronics level. Finally, an innovative distribution of light sources and detectors and a dedicated signal processing procedure resolve the anatomical heterogeneity of different phalanx topologies, compensate low perfusion indexes due to the phalanx anatomy and estimates equivalent pulse oximetry SpO2 indexes. First in-vivo validation results of the novel sensor are discussed at the end of the paper.
PMID: 17946619 [PubMed - indexed for MEDLINE]
[Read more →]
Tags: Conf Proc IEEE Eng Med Biol Soc
Ultrasound-guided noninvasive measurement of a patient’s central venous pressure.
Conf Proc IEEE Eng Med Biol Soc. 2006;1:3843-9
Authors: Aggarwal V, Chatterjee A, Cho Y, Cheung D
Central venous pressure (CVP) is an important physiological parameter, the correct measure of which is a clinically relevant diagnostic tool for heart failure patients. A current challenge for physicians, however, is to obtain a quick and accurate measure of a patient’s CVP in a manner that poses minimum discomfort. Current approaches for measuring CVP involve invasive methods such as threading a central venous catheter along a major vein, or tedious physical exams that require physicians to grossly estimate the measurement. Our solution proposes a novel noninvasive method to estimate central venous pressure using ultrasound-guided surface pressure measurement. Specifically, our device works in conjunction with an ultrasound machine and probe that is used to visualize the interior jugular (IJ) vein below the surface of the skin on a patient’s neck. Once the interior jugular vein is located, our device detects the pressure on the skin required to collapse the IJ and correlates this value to a central venous pressure reading reported to the operator. This quick and noninvasive measurement is suitable for emergency situations or primary care settings where rapid diagnosis of a patient’s CVP is required, and prevents the need for further invasive and costly procedures. The measurement procedure is also simple enough to be performed by operators without extensive medical training.
PMID: 17946583 [PubMed - indexed for MEDLINE]
[Read more →]
Tags: Conf Proc IEEE Eng Med Biol Soc