Virtual Journal Club

Please note: This website is for discussion purposes only. The information provided at this website is not intended to provide treatment advice, or to diagnose or treat any medical disorder. The creator of this website is not responsible for events that occur as a result of decisions made based on the information presented here.

Citations powered by PubMed

Ultrasound Accurately Reflects the Jugular Venous Examination but Underestimates Central Venous Pressure.

August 28th, 2010 · Start a Discussion

Related Articles

Ultrasound Accurately Reflects the Jugular Venous Examination but Underestimates Central Venous Pressure.

Chest. 2010 Aug 26;

Authors: Schmidt GA, Deol GR, Collett N, Ashby A

Abstract: BACKGROUND: Bedside ultrasound examination could be used to assess the jugular venous pressure (JVP), and thus central venous pressure (CVP), more reliably than clinical examination. METHODS: The study was a prospective, blinded evaluation comparing physical examination of External jugular venous pressure (JVPEXT), Internal jugular venous pressure (JVPINT) and Ultrasound collapse pressure (UCP) with CVP measured using an indwelling catheter. We compared the examination of the external and internal jugular venous pressure with each other and with the UCP and CVP. JVPEXT, JVPINT, UCP, and CVP were compared graphically using Bland-Altman plots and correlation coefficients were calculated. RESULTS: The correlation coefficients comparing CVP to UCP, JVPEXT, and JVPINT were 0.62, 0.57, and 0.50, respectively. When UCP was compared to JVPEXT and JVPINT, correlation coefficients were 0.91 and 0.81, respectively. Lastly, the correlation coefficient comparing JVPEXT and JVPINT was 0.98. The Bland-Altman graphical comparison of methods technique revealed that CVP was often underestimated by UCP, and clinical examination of JVPEXT and JVPINT. In contrast, there was no systematic bias between UCP and either JVPEXT or JVPINT, nor between JVPEXT and JVPINT CONCLUSION: Ultrasound examination is capable of measuring accurately the JVP as judged from the internal or external jugular vein. However, like the JVP, ultrasound typically underestimates CVP. A systematic bias between UCP and CVP suggests the presence of a variable degree of venous tone, possibly signaling contraction of jugular venous smooth muscle. Trial Registration: Clinicaltrials.gov Identifier: NCT01099241.

PMID: 20798190 [PubMed - as supplied by publisher]

Link to Abstract at PubMed

Share


Tags: Chest

0 responses so far ↓

  • There are no comments yet...Kick things off by filling out the form below.

Discuss this article